Vedhan 150 Vedhan 150 for Solar Energy Projects in India

Vedhan 150

Vedhan 150 Pole Erection Machine for Solar

Vedhan 150

Vedhan 150 | Attachment

Support Vehicle

Tractor

Horsepower

35 - 60 HP

Hole digging rate

60 - 120 holes/hour

Hole Depth

900 mm

Required Hydraulic Flow

10-20 LPM

Required Hydraulic Pressure

120 - 160 bar

Hole Diameter

150-300 mm

Solar Project Fit

In utility-scale solar projects, foundation requirements often extend beyond standard shallow drilling, especially for larger mounting structures, high-wind zones, and installations requiring deeper structural stability. These sites frequently involve dense soil layers, murram, and deeper compact strata, making conventional shallow drilling equipment insufficient. The Vedhan 150 is designed to meet these requirements by enabling deep, high-capacity hole drilling for critical solar infrastructure using a tractor-mounted system. Operating with 20-60 HP tractors, the machine allows solar EPC contractors to execute deep foundation drilling operations without depending on heavy standalone rigs. This is particularly useful in solar projects where varying foundation depths are required across module mounting systems, fencing lines, and structural supports distributed across large project areas. With the capability to drill holes up to 1500 mm deep and diameters ranging from 150-450 mm, the Vedhan 150 supports both standard and heavy-duty solar foundation requirements. Its drilling system is built for controlled penetration into deeper soil layers, ensuring structural reliability and alignment even in challenging ground conditions.

FIELD PRIORITIES

  • Drilling rate: 8-15 holes per hour (depending on soil conditions)
  • Stable single hitch mounting system for controlled operation
  • Suitable for compact soil, murram, and semi-rocky terrain

PROJECT EXECUTION

How the Vedhan 150 fits the worksite

Solar Energy

Use Case Applications - Solar, Utility Corridors & Last-Mile Connectivity

The Vedhan 150 is suited for advanced drilling requirements across solar installations, including deep foundation drilling for solar module mounting structures, drilling for heavy-duty fencing posts and perimeter systems, installation of high-load electrical poles and support structures, foundation preparation for inverter stations and utility installations, and drilling across deep compact soil layers and semi-rocky conditions.

Its extended depth capability ensures that varying structural requirements within a solar project can be handled efficiently using a single tractor-mounted solution.

Vedhan 150 Pole Installation Machine for Solar
Vedhan 150 Pole Installation Machine for Solar

Solar Energy

Execution Priorities for Solar

Solar EPC projects require precise and stable deep foundation work, where drilling quality directly impacts structural strength and long-term performance. The Vedhan 150 is designed to maintain consistent drilling efficiency even at increased depths. The deep drilling capability up to 1500 mm allows operators to meet higher foundation depth requirements without additional equipment, reducing operational complexity on-site.

The wider hole diameter range up to 450 mm supports heavy structural installations, ensuring stronger base support for mounting systems and utility structures. The stable single hitch mounting system ensures balanced operation during deep drilling, minimizing vibration and improving control across varying soil conditions.

The controlled drilling rate ensures steady penetration, reducing stress on components while maintaining consistent hole quality across the project. By integrating these capabilities, the machine supports reliable deep foundation execution, reduced equipment dependency, and improved structural consistency across large solar installations.

WORKFLOW

From route planning to handoff

1

Route Planning

Map route requirements, trench depth, and site access before deploying Vedhan 150.

2

Controlled Trenching

Use the attachment setup to keep trench output consistent across solar park rows, inverter blocks, and power evacuation corridors.

3

Installation Handoff

Cleaner trench profiles help cable laying, earthing, backfilling, and commissioning teams proceed with less rework.

4

Support And Sizing

Autocracy Machinery can help match machine configuration, brochure details, and application guidance to the project.

APPLICATION SUPPORT

Need Vedhan 150 for Solar Energy?

Share your site conditions, output goals, and timeline so the Autocracy team can guide model fit, brochure details, and next steps for your project.

Precision Machines. Project-Ready.

Built for performance. Trusted by contractors, municipalities, and EPC teams across sectors.

FeatureValue
Machine Overall Length2200 - 2400 mm
Machine Overall Width800 - 1000 mm
Machine Overall Height1600 - 1800 mm
Machine Weight150 - 300 kg

Solar Energy FAQs

Common questions about using Vedhan 150 in this application.

More Models in Vedhan Series

Pole erection machine | Equipment

Mayura P Pole erection machine
Support VehicleTractor
Horsepower>50 HP
Transmission TypePTO / Hydraulic

| Attachment

Vedhan 50 Post Hole Digger
Support VehicleTractor
Horsepower35 – 60 HP
Hole digging rate60 – 120 holes/hour

Industry model fit in India

Vedhan 150 Vedhan 150 for Solar Energy in India

Vedhan 150 Vedhan 150 is presented for Solar Energy applications on India project sites, where a attachment has to work around solar parks, cable corridors, pile rows, open sites, and long internal utility runs. This page adds india-focused context for post hole digger, so teams can judge whether the model supports repeatable output, cable-route accuracy, panel-field access, and EPC schedule control.

Start by checking Vedhan 150 against array layout, cable depth, tracker clearance, soil profile, and commissioning milestones; that route-specific review is more useful than treating every post hole digger page as the same model brochure.

Common solar energy use cases for Vedhan 150 include DC cable trenches, earthing routes, tracker support works, inverter corridors, and solar EPC utilities, provided the site setup supports the machine, crew movement, and next work stage properly.

Use this model page to discuss Solar Energy fit, specification limits, transport readiness, brochure details, and quote requirements with Autocracy Machinery.

project teams in India should confirm hole specification, erection workflow, transport readiness, and pole or post type before shortlisting Vedhan 150, especially when solar parks, cable corridors, pile rows, open sites, and long internal utility runs affect access or productivity.